Replacing a Straight Air Line with Coiled PU Tubing: What to Measure
Before replacing a straight pneumatic tube with a coiled one, measure the distance between the connection points at the nearest and farthest working positions. Then check where the coil will sit at rest. The length of the old straight tube alone does not tell you which coil will fit.

1. Measure the distance at both ends of travel
Record the minimum and maximum distance between the connection points. Mark the actual path the line must follow around guards, frames or equipment. If the line cannot run directly between its connections, include a photo or drawing of the route when requesting a recommendation.
AISILI lists coiled PU tubing by working reach, from 3 to 15 m. A 5 m option means the two ends can be extended to a working distance of 5 m during use. It does not mean the tubing material would measure 5 m if fully straightened.
2. Check where the coil will sit when retracted
Record the available space at the parked position, including nearby doors, tools and moving parts. Note whether the coil will hang vertically or sit horizontally. Ask for the retracted dimensions and end configuration of the model under review; do not infer them from the working reach.
Check clearance through the full movement path so the coil cannot catch on nearby equipment or pull sideways on the connections.
3. Identify the tube and both connections
Record the tube outside diameter (OD) and inside diameter (ID) separately. Photograph the tube markings and fittings at both ends. Note whether each end uses a push-to-connect fitting or another connection, and identify the thread separately where applicable.
An existing fitting that accepts the tube OD does not establish that the new assembly meets the same airflow or pressure requirements. Review the PU tube size and pressure guide if the original specification is incomplete.
4. Confirm the operating conditions before ordering
Share the working pressure, temperature, expected movement and any oil, moisture, heat or abrasion exposure. Check the tubing and fittings against the actual conditions. If the installation does not need to extend and retract, a supported straight route may still be the better choice. See the coiled vs straight PU tubing guide for the layout comparison.
What to send for a replacement quote
- Minimum and maximum connection distance, with units.
- Space available for the retracted coil and photos of the route.
- Existing tube OD × ID and photos or model numbers of both fittings.
- Working pressure, temperature, exposure conditions and quantity.
Review AISILI coiled PU tubing specifications or send AISILI your replacement measurements.



